The role of atrial modeling in the development of ECG processing tools
dc.contributor.author | Jacquemet, Vincent | |
dc.contributor.author | Lemay, Mathieu | |
dc.contributor.author | Uldry, Laurent | |
dc.contributor.author | Duchêne, Cédric | |
dc.contributor.author | Van Oosterom, Adriaan | |
dc.contributor.author | Kappenberger, Lukas | |
dc.contributor.author | Vesin, Jean-Marc | |
dc.date.accessioned | 2024-04-29T13:31:01Z | |
dc.date.available | NO_RESTRICTION | fr |
dc.date.available | 2024-04-29T13:31:01Z | |
dc.date.issued | 2009 | |
dc.identifier.uri | http://hdl.handle.net/1866/32997 | |
dc.publisher | Springer | fr |
dc.subject | Atrial fibrillation | fr |
dc.subject | Ventricular activity | fr |
dc.subject | Equivalent dipole | fr |
dc.subject | Torso model | fr |
dc.subject | Electrophysiological model | fr |
dc.title | The role of atrial modeling in the development of ECG processing tools | fr |
dc.type | Contribution à un congrès / Conference object | fr |
dc.contributor.affiliation | Université de Montréal. Faculté de médecine. Département de pharmacologie et physiologie | fr |
dc.identifier.doi | 10.1007/978-3-642-03882-2_114 | |
dcterms.abstract | The standard ECG remains the most common non-invasive tool for assessing atrial fibrillation. Specific signal processing techniques have been developed to improve the diagnosis. However, validation of such tools is challenging and comprehensive invasive data may not easily be obtained. To facilitate this task, we developed a computer model of the atria. In this electrophysiological model, atrial fibrillation was simulated and the manifestation of its electrical activity on the thorax was computed. The resulting realistic-looking synthetic ECG signals were used as benchmarks for testing, evaluating and comparing ECG processing techniques such as cancellation of the ventricular activity, vectorcardiography and dominant frequency analysis. | fr |
dcterms.isPartOf | urn:ISBN:9783642038822 | fr |
dcterms.isPartOf | urn:ISBN:9783642038815 | fr |
dcterms.language | eng | fr |
oaire.citationTitle | World congress on medical physics and biomedical engineering | fr |
oaire.citationStartPage | 429 | fr |
oaire.citationEndPage | 432 | fr |
oaire.citationConferencePlace | Munich (Allemagne) | fr |
oaire.citationConferenceDate | 2009-09-07 - 2009-09-12 | fr |
Fichier·s constituant ce document
Ce document figure dans la ou les collections suivantes
Ce document diffusé sur Papyrus est la propriété exclusive des titulaires des droits d'auteur et est protégé par la Loi sur le droit d'auteur (L.R.C. (1985), ch. C-42). Il peut être utilisé dans le cadre d'une utilisation équitable et non commerciale, à des fins d'étude privée ou de recherche, de critique ou de compte-rendu comme le prévoit la Loi. Pour toute autre utilisation, une autorisation écrite des titulaires des droits d'auteur sera nécessaire.