Afficher la notice

dc.contributor.authorCeglia, Amedeo
dc.contributor.authorBailly, François
dc.contributor.authorBegon, Mickaël
dc.date.accessioned2023-07-10T12:39:17Z
dc.date.availableNO_RESTRICTIONfr
dc.date.available2023-07-10T12:39:17Z
dc.date.issued2023-07-04
dc.identifier.urihttp://hdl.handle.net/1866/28359
dc.publisherInstitute of electrical and electronics engineersfr
dc.subjectModeling and simulating humansfr
dc.subjectPhysical human-robot interactionfr
dc.subjectSensor-based controlfr
dc.titleMoving horizon estimation of human kinematics and muscle forcesfr
dc.typeArticlefr
dc.contributor.affiliationUniversité de Montréal. Faculté de médecine. Département de pharmacologie et physiologiefr
dc.identifier.doi10.1109/LRA.2023.3291921
dcterms.abstractHuman-robot interaction based on real-time kinematics or electromyography (EMG) feedback improves rehabilitation using assist-as-needed strategies. Muscle forces are expected to provide even more comprehensive information than EMG to control these assistive rehabilitation devices. Measuring in vivo muscle force is challenging, leading to the development of numerical methods to estimate them. Due to their high computational cost, forward dynamics-based optimization algorithms were not viable for real-time estimation until recently. To achieve muscle forces estimation in real time, a moving horizon estimator (MHE) algorithm was used to track experimental biosignals. Two participants were equipped with EMG sensors and skin markers that were streamed in real time and used as targets for the MHE. The upper-limb musculoskeletal (MSK) model was composed of 10 degrees-of-freedom actuated by 31 muscles. The MHE relies on a series of overlapping trajectory optimization subproblems of which the following parameters have been adjusted: the fixed duration and the frame to export. We based this adjustment on the estimation delay, the muscle saturation, the joint kinematic mean power frequency, and errors to experimental data. Our algorithm provided consistent estimates of muscle forces and kinematics with visual feedback at 30 Hz with a 110 ms delay. This method is promising to guide rehabilitation and enrich assistive device control laws with personalized force estimations.fr
dcterms.isPartOfurn:ISSN:2377-3766fr
dcterms.languageengfr
UdeM.ReferenceFournieParDeposant10.1109/LRA.2023.3291921fr
UdeM.VersionRioxxVersion acceptée / Accepted Manuscriptfr
oaire.citationTitleIEEE Robotics and automation lettersfr


Fichier·s constituant ce document

Vignette

Ce document figure dans la ou les collections suivantes

Afficher la notice

Ce document diffusé sur Papyrus est la propriété exclusive des titulaires des droits d'auteur et est protégé par la Loi sur le droit d'auteur (L.R.C. (1985), ch. C-42). Il peut être utilisé dans le cadre d'une utilisation équitable et non commerciale, à des fins d'étude privée ou de recherche, de critique ou de compte-rendu comme le prévoit la Loi. Pour toute autre utilisation, une autorisation écrite des titulaires des droits d'auteur sera nécessaire.