Electrostatic screening length in “soft” electrolyte solutions
dc.contributor.author | Adibnia, Vahid | |
dc.contributor.author | Shrestha, Budha Ratna | |
dc.contributor.author | Mirbagheri, Marziye | |
dc.contributor.author | Murschel, Frederic | |
dc.contributor.author | De Crescenzo, Gregory | |
dc.contributor.author | Banquy, Xavier | |
dc.date.accessioned | 2020-03-27T19:03:54Z | |
dc.date.available | MONTHS_WITHHELD:12 | fr |
dc.date.available | 2020-03-27T19:03:54Z | |
dc.date.issued | 2019-07-30 | |
dc.identifier.uri | http://hdl.handle.net/1866/23154 | |
dc.publisher | American Chemical Society | fr |
dc.title | Electrostatic screening length in “soft” electrolyte solutions | fr |
dc.type | Article | fr |
dc.contributor.affiliation | Université de Montréal. Faculté de pharmacie | fr |
dc.identifier.doi | 10.1021/acsmacrolett.9b00437 | |
dcterms.abstract | Using the Surface Forces Apparatus on solutions of polymeric ions, the effect of specific ion–ion correlations is evaluated on the characteristic decay length, λ, of screened electrostatic interactions between charged surfaces. Electrolyte solutions composed of point charges surrounded by repulsive polymeric shells were used to elucidate the role of ions size and size asymmetry between co- and counterions on the screening of electrostatic forces. In electrolytes composed of large polymeric cations and small point-charge anions, because of the steric and excluded volume effects, the screening length follows the simple scaling relation λ ∼ d, where d is the characteristic size of the large cation. It is also reported that both co- and counterion sizes affect the thickness of the electrical double layer and influence the screened electrostatic interactions. In solutions of polymeric cation/anion pairs, the screening length is shown to depend on an asymmetry factor. These results provide insights into correlation effects in electrolytes, which were so far unreachable experimentally and help elucidate such effects in electronics, energy storage devices, and biomedical systems. | fr |
dcterms.isPartOf | urn:ISSN:2161-1653 | fr |
dcterms.language | eng | fr |
UdeM.ReferenceFournieParDeposant | Electrostatic screening length in “soft” electrolyte solutions | fr |
UdeM.VersionRioxx | Version originale de l'auteur·e / Author's Original | fr |
oaire.citationTitle | ACS Macro letters | |
oaire.citationVolume | 8 | |
oaire.citationIssue | 8 | |
oaire.citationStartPage | 1017 | |
oaire.citationEndPage | 1021 |
Files in this item
This item appears in the following Collection(s)
This document disseminated on Papyrus is the exclusive property of the copyright holders and is protected by the Copyright Act (R.S.C. 1985, c. C-42). It may be used for fair dealing and non-commercial purposes, for private study or research, criticism and review as provided by law. For any other use, written authorization from the copyright holders is required.