Afficher la notice

dc.contributor.authorSeoud, Lama
dc.contributor.authorCheriet, Farida
dc.contributor.authorLabelle, Hubert
dc.contributor.authorDansereau, Jean
dc.date.accessioned2016-02-15T18:53:22Z
dc.date.availableNO_RESTRICTIONfr
dc.date.available2016-02-15T18:53:22Z
dc.date.issued2009-09-29
dc.identifier.urihttp://hdl.handle.net/1866/13058
dc.description.sponsorshipNatural Sciences and Engineering Research Council of Canada and MENTOR, a strategic training program of the Canadian Institutes of Health Research.fr
dc.subject3D reconstruction
dc.subjectRib cage
dc.subjectX-rays
dc.subjectSurface topography
dc.titleA novel method for the 3-D reconstruction of scoliotic ribs from frontal and lateral radiographsfr
dc.typeArticlefr
dc.contributor.affiliationUniversité de Montréal. Faculté de médecine. Département de chirurgiefr
dc.identifier.doi10.1109/TBME.2009.2032530
dcterms.abstractAmong the external manifestations of scoliosis, the rib hump, which is associated with the ribs' deformities and rotations, constitutes the most disturbing aspect of the scoliotic deformity for patients. A personalized 3-D model of the rib cage is important for a better evaluation of the deformity, and hence, a better treatment planning. A novel method for the 3-D reconstruction of the rib cage, based only on two standard radiographs, is proposed in this paper. For each rib, two points are extrapolated from the reconstructed spine, and three points are reconstructed by stereo radiography. The reconstruction is then refined using a surface approximation. The method was evaluated using clinical data of 13 patients with scoliosis. A comparison was conducted between the reconstructions obtained with the proposed method and those obtained by using a previous reconstruction method based on two frontal radiographs. A first comparison criterion was the distances between the reconstructed ribs and the surface topography of the trunk, considered as the reference modality. The correlation between ribs axial rotation and back surface rotation was also evaluated. The proposed method successfully reconstructed the ribs of the 6th-12th thoracic levels. The evaluation results showed that the 3-D configuration of the new rib reconstructions is more consistent with the surface topography and provides more accurate measurements of ribs axial rotation.fr
dcterms.languageengfr
UdeM.VersionRioxxVersion acceptée / Accepted Manuscript
oaire.citationTitleIEEE transactions on biomedical engineering
oaire.citationVolume58
oaire.citationIssue5
oaire.citationStartPage1135
oaire.citationEndPage1146


Fichier·s constituant ce document

Vignette

Ce document figure dans la ou les collections suivantes

Afficher la notice

Ce document diffusé sur Papyrus est la propriété exclusive des titulaires des droits d'auteur et est protégé par la Loi sur le droit d'auteur (L.R.C. (1985), ch. C-42). Il peut être utilisé dans le cadre d'une utilisation équitable et non commerciale, à des fins d'étude privée ou de recherche, de critique ou de compte-rendu comme le prévoit la Loi. Pour toute autre utilisation, une autorisation écrite des titulaires des droits d'auteur sera nécessaire.