Patient-specific model of a scoliotic torso for surgical planning
dc.contributor.author | Harmouche, Rola | |
dc.contributor.author | Cheriet, Farida | |
dc.contributor.author | Labelle, Hubert | |
dc.contributor.author | Dansereau, Jean | |
dc.date.accessioned | 2015-10-27T17:05:29Z | |
dc.date.available | NO_RESTRICTION | fr |
dc.date.available | 2015-10-27T17:05:29Z | |
dc.date.issued | 2013-03 | |
dc.identifier.uri | http://hdl.handle.net/1866/12511 | |
dc.description.sponsorship | Canadian Institute of Health Research (CIHR) | fr |
dc.subject | Multimodal image registration | en |
dc.subject | Inter-patient registration | en |
dc.subject | Model to patient registration | en |
dc.subject | Scoliosis | en |
dc.subject | Scoliose | fr |
dc.title | Patient-specific model of a scoliotic torso for surgical planning | en |
dc.type | Article | |
dc.contributor.affiliation | Université de Montréal. Faculté de médecine. Département de chirurgie | fr |
dc.identifier.doi | 10.1117/12.2007753 | |
dcterms.abstract | A method for the construction of a patient-specific model of a scoliotic torso for surgical planning via inter- patient registration is presented. Magnetic Resonance Images (MRI) of a generic model are registered to surface topography (TP) and X-ray data of a test patient. A partial model is first obtained via thin-plate spline registration between TP and X-ray data of the test patient. The MRIs from the generic model are then fit into the test patient using articulated model registration between the vertebrae of the generic model’s MRIs in prone position and the test patient’s X-rays in standing position. A non-rigid deformation of the soft tissues is performed using a modified thin-plate spline constrained to maintain bone rigidity and to fit in the space between the vertebrae and the surface of the torso. Results show average Dice values of 0.975 ± 0.012 between the MRIs following inter-patient registration and the surface topography of the test patient, which is comparable to the average value of 0.976 ± 0.009 previously obtained following intra-patient registration. The results also show a significant improvement compared to rigid inter-patient registration. Future work includes validating the method on a larger cohort of patients and incorporating soft tissue stiffness constraints. The method developed can be used to obtain a geometric model of a patient including bone structures, soft tissues and the surface of the torso which can be incorporated in a surgical simulator in order to better predict the outcome of scoliosis surgery, even if MRI data cannot be acquired for the patient. | en |
dcterms.isPartOf | urn:ISSN:1996-756X | |
dcterms.isPartOf | urn:ISSN:0277-786X | |
dcterms.language | eng | fr |
UdeM.VersionRioxx | Version originale de l'auteur·e / Author's Original | |
oaire.citationTitle | Proceedings of SPIE | |
oaire.citationVolume | 8671 |
Files in this item
This item appears in the following Collection(s)
This document disseminated on Papyrus is the exclusive property of the copyright holders and is protected by the Copyright Act (R.S.C. 1985, c. C-42). It may be used for fair dealing and non-commercial purposes, for private study or research, criticism and review as provided by law. For any other use, written authorization from the copyright holders is required.