Show item record

dc.contributor.advisorRouleau, Dominique
dc.contributor.advisorPetit, Yvan
dc.contributor.authorChapleau, Julien
dc.date.accessioned2013-03-27T15:44:03Z
dc.date.availableNO_RESTRICTIONen
dc.date.available2013-03-27T15:44:03Z
dc.date.issued2013-03-01
dc.date.submitted2012-10
dc.identifier.urihttp://hdl.handle.net/1866/9224
dc.subjectAmplitude de mouvementen
dc.subjectMobilitéen
dc.subjectRadiographieen
dc.subjectCoudeen
dc.subjectGoniométrieen
dc.subjectRange of motionen
dc.subjectElbowen
dc.subjectGoniometryen
dc.subjectRadiographyen
dc.subjectMobilityen
dc.subject.otherHealth Sciences - Medicine and Surgery / Sciences de la santé - Médecine et chirurgie (UMI : 0564)en
dc.titleAmplitude de mouvement du coude, développement d’une méthode de mesure radiographique et identification des facteurs influents
dc.typeThèse ou mémoire / Thesis or Dissertation
etd.degree.disciplineSciences biomédicalesen
etd.degree.grantorUniversité de Montréalfr
etd.degree.levelMaîtrise / Master'sen
etd.degree.nameM. Sc.en
dcterms.abstractL’instrument le plus fréquemment utilisé pour la mesure de l’amplitude de mouvement du coude est le goniomètre universel. Or celui-ci ne fait pas l’unanimité : plusieurs auteurs remettent en question sa fiabilité et validité. Cette étude détaille donc, en trois étapes, une alternative beaucoup plus précise et exacte : une méthode radiographique de mesure. Une étude de modélisation a d’abord permis de repérer les sources d’erreur potentielles de cette méthode radiographique, à ce jour jamais utilisée pour le coude. La méthode a ensuite servi à évaluer la validité du goniomètre. À cette fin, 51 volontaires ont participé à une étude clinique où les deux méthodes ont été confrontées. Finalement, la mesure radiographique a permis de lever le voile sur l’influence que peuvent avoir différents facteurs démographiques sur l’amplitude de mouvement du coude. La méthode radiographique s’est montrée robuste et certaines sources d’erreurs facilement évitables ont été identifiées. En ce qui concerne l’étude clinique, l’erreur de mesure attribuable au goniomètre était de ±10,3° lors de la mesure du coude en extension et de ±7,0° en flexion. L’étude a également révélé une association entre l’amplitude de mouvement et différents facteurs, dont les plus importants sont l’âge, le sexe, l’IMC et la circonférence du bras et de l’avant-bras. En conclusion, l’erreur du goniomètre peut être tolérée en clinique, mais son utilisation est cependant déconseillée en recherche, où une erreur de mesure de l’ordre de 10° est inacceptable. La méthode radiographique, étant plus précise et exacte, représente alors une bien meilleure alternative.en
dcterms.abstractThe most commonly used instrument for elbow range of motion measurement is the universal goniometer. However great controversy remains regarding its reliability and validity. Hence this study presents an accurate and precise alternative: a radiographic method of measurement. The limits of the radiographic method and potential sources of error were first evaluated through a biomechanical study. Fifty-one volunteers then participated in a clinical study in which this radiographic method was compared to the goniometer for elbow range of motion measurement. Finally, the great precision of radiographic measurements allowed us to study the potential influence of various demographic and anthropometric factors on elbow range of motion in the last part of this work. Regarding the clinical study, the goniometric and radiographic methods differ but they correlate. The goniometer’s measurement error was ±10.3° during extension measurement and ±7.0 ° for flexion. Secondly, the radiographic method provides consistent results despite malpositioning of the upper limb during radiographic image acquisition and easily preventable sources of error were identified. The study finally found an association between the range of motion and various factors, including age, sex, BMI, and the arm and forearm circumferences. In conclusion, error associated with the use of the goniometer could be tolerated in a clinical setting, the instrument being both inexpensive and simple to use. However, its use is discouraged in the research context, where a measurement error of 10° is unacceptable. The radiographic method, being more precise and accurate, represents a much better alternative.en
dcterms.languagefraen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show item record

This document disseminated on Papyrus is the exclusive property of the copyright holders and is protected by the Copyright Act (R.S.C. 1985, c. C-42). It may be used for fair dealing and non-commercial purposes, for private study or research, criticism and review as provided by law. For any other use, written authorization from the copyright holders is required.