Show item record

dc.contributor.advisorCloutier, Guy
dc.contributor.advisorSoulez, Gilles
dc.contributor.authorValiallah, Hasti
dc.date.accessioned2013-01-24T17:41:08Z
dc.date.availableNO_RESTRICTIONen
dc.date.available2013-01-24T17:41:08Z
dc.date.issued2013-01-04
dc.date.submitted2012-10
dc.identifier.urihttp://hdl.handle.net/1866/8945
dc.subjectplaque vulnérableen
dc.subjectélastographie ultrasonore non-invasiveen
dc.subjectélastographie ultrasonore invasiveen
dc.subjectdéformation axialeen
dc.subjectmodèle porcinen
dc.subjecthistologieen
dc.subjectvulnerable plaqueen
dc.subjectnon-invasive ultrasound elastographyen
dc.subjectinvasive ultrasound elastographyen
dc.subjectaxial strainen
dc.subjectporcine modelen
dc.subjecthistologyen
dc.subject.otherEngineering - Biomedical / Ingénierie - Biomédicale (UMI : 0541)en
dc.titleValidation in-vivo des techniques d’élastographie ultrasonore, invasive et non-invasive, à l’aide d’un modèle porcinen
dc.typeThèse ou mémoire / Thesis or Dissertation
etd.degree.disciplineGénie biomédicalen
etd.degree.grantorUniversité de Montréalfr
etd.degree.levelMaîtrise / Master'sen
etd.degree.nameM. Sc. A.en
dcterms.abstractIl est maintenant admis que la composition de la plaque athérosclérotique est un déterminant majeur de sa vulnérabilité à se rompre. Vu que la composition de la plaque affecte ses propriétés mécaniques, l'évaluation locale des propriétés mécaniques de la plaque d'athérome peut nous informer sur sa vulnérabilité. L'objectif est de comparer les techniques d’élastographie ultrasonores endovasculaire (EVE) et non-invasive (NIVE) en fonction de leur potentiel à identifier les composantes calcifiées et lipidiques de la plaque. Les acquisitions intravasculaire et extravasculaire ont été effectuées sur les artères carotidiennes de neuf porcs hypercholestérolémiques à l’aide d’un cathéter de 20 MHz et d'une sonde linéaire de 7.5 MHz, respectivement. Les valeurs de déformation radiale et axiale, rapportés par EVE et NIVE, ont été corrélées avec le pourcentage des zones histologiques calcifiées et lipidiques pour cinq plaques. Nos résultats démontrent une bonne corrélation positive entre les déformations et les composantes calcifiées (r2 = 0.82, P = 0.034 valeur par EVE et r2 = 0.80, P = 0.041 valeur par NIVE). Une forte corrélation entre les déformations axiales et les contenus lipidiques par NIVE (r2 = 0.92, P-value = 0.010) a été obtenue. En conclusion, NIVE et EVE sont des techniques potentielles pour identifier les composants de la plaque et aider les médecins à diagnostiquer précocement les plaques vulnérables.en
dcterms.abstractIt is now widely accepted that plaque composition is a major determinant of plaque’s vulnerability to rupture. Since composition of the plaque affects its mechanical properties, the local assessment of mechanical properties of atherosclerotic plaque may inform us about plaque’s vulnerability. The objective is to compare ultrasonic endovascular elastography (EVE) versus non-invasive vascular elastography (NIVE) according to their potential to identify plaque contents. Intravascular and extravascular acquisitions were performed on carotid arteries of nine hypercholesterolemic minipigs with a 20 MHz catheter and a 7.5 MHz standard probe, respectively. Radial and axial strain values, reported by EVE and NIVE respectively, were correlated with histological area of lipid and calcium for five plaques. Our results demonstrate a good positive correlation between strains and calcified contents (r2=0.82, P-value=0.034 by EVE and r2=0.80, P-value= 0.041 by NIVE). Additionally, there is a strong correlation between axial strains and lipid contents by NIVE (r2=0.92, P-value= 0.010). In conclusion, NIVE and EVE are the potential techniques to identify plaque components and to help physicians to early diagnose the vulnerable plaques.en
dcterms.languagefraen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show item record

This document disseminated on Papyrus is the exclusive property of the copyright holders and is protected by the Copyright Act (R.S.C. 1985, c. C-42). It may be used for fair dealing and non-commercial purposes, for private study or research, criticism and review as provided by law. For any other use, written authorization from the copyright holders is required.