Afficher la notice

dc.contributor.advisorMathieu, Pierre A.
dc.contributor.advisorBertrand, Michel
dc.contributor.authorNejat, Nahal
dc.date.accessioned2012-12-13T19:27:32Z
dc.date.availableNO_RESTRICTIONen
dc.date.available2012-12-13T19:27:32Z
dc.date.issued2012-11-02
dc.date.submitted2012-08
dc.identifier.urihttp://hdl.handle.net/1866/8819
dc.subjectBiceps brachialen
dc.subjectBIceps brachiien
dc.subjectCompartimenten
dc.subjectcompartmenten
dc.subjectMatrice d'électrodesen
dc.subjectElectrode arrayen
dc.subjectEMG de surfaceen
dc.subjectSurface EMGen
dc.subjectÉchoen
dc.subjectUltrasounden
dc.subject.otherEngineering - Biomedical / Ingénierie - Biomédicale (UMI : 0541)en
dc.titleStudy on the activation of the biceps brachii compartments in normal subjectsen
dc.typeThèse ou mémoire / Thesis or Dissertation
etd.degree.disciplineGénie biomédicalen
etd.degree.grantorUniversité de Montréalfr
etd.degree.levelMaîtrise / Master'sen
etd.degree.nameM. Sc. A.en
dcterms.abstractLes prothèses myoélectriques modernes peuvent être dotées de plusieurs degrés de liberté ce qui nécessite plusieurs signaux musculaires pour en exploiter pleinement les capacités. Pour obtenir plus de signaux, il nous a semblé prometteur d'expérimenter si les 6 compartiments du biceps brachial pouvaient être mis sous tension de façon volontaire et obtenir ainsi 6 signaux de contrôle au lieu d'un seul comme actuellement. Des expériences ont donc été réalisées avec 10 sujets normaux. Des matrices d'électrodes ont été placées en surface au-dessus du chef court et long du biceps pour recueillir les signaux électromyographiques (EMG) générés par le muscle lors de contractions effectuées alors que les sujets étaient soit assis, le coude droit fléchi ~ 100 ° ou debout avec le bras droit tendu à l'horizontale dans le plan coronal (sur le côté). Dans ces deux positions, la main était soit en supination, soit en position neutre, soit en pronation. L'amplitude des signaux captés au-dessus du chef court du muscle a été comparée à ceux obtenus à partir du chef long. Pour visualiser la forme du biceps sous les électrodes l'imagerie ultrasonore a été utilisée. En fonction de la tâche à accomplir, l'activité EMG a était plus importante soit dans un chef ou dans l'autre. Le fait de pouvoir activer préférentiellement l'un des 2 chefs du biceps, même si ce n'est pas encore de façon complètement indépendante, suggère que l'utilisation sélective des compartiments pourrait être une avenue possible pour faciliter le contrôle des prothèses myoélectriques du membre supérieur.en
dcterms.abstractThe latest myoelectric prostheses have several degrees of freedom and therefore require a large number of myoelectric signals to fully exploit their capabilities. Muscle compartments, which are intra-muscular subdivisions innervated by an individual muscle nerve branch, can be exploited to provide additional independent muscle control sites to operate such prostheses. This research presents a work to investigate the activation of the 6 biceps brachii compartments in healthy subjects to see if they have the ability to activate those compartments voluntarily. Therefore, electromyographic (EMG) signals were recorded from an array of seven and ten pairs of equally spaced surface electrodes positioned across the short and long head of the biceps of ten healthy subjects. The EMG signals are collected in two positions: 1) with the subject seated, right elbow flexed ~100°, and 2) with the subject standing with the right arm extended horizontally in the coronal plane (90°shoulder abduction). In both positions, the hand is either fully supinated, neutral, or fully pronated. The average root mean square value of the EMG signals obtained from the pairs of electrodes positioned over the short head are compared with the average obtained for the other pairs placed over the biceps long head. Ultrasound imaging also used to visualize the long and short heads of the biceps in flexed and extended arm while the hand was in different postures. Depending on the task to be accomplished, activity was larger in one head or in the other. Being able to activate either head of the biceps, while not yet completely independently, suggests that the selective use of compartments could be a possible avenue for controlling upper limb myoelectric prostheses.en
dcterms.languageengen


Fichier·s constituant ce document

Vignette

Ce document figure dans la ou les collections suivantes

Afficher la notice

Ce document diffusé sur Papyrus est la propriété exclusive des titulaires des droits d'auteur et est protégé par la Loi sur le droit d'auteur (L.R.C. (1985), ch. C-42). Il peut être utilisé dans le cadre d'une utilisation équitable et non commerciale, à des fins d'étude privée ou de recherche, de critique ou de compte-rendu comme le prévoit la Loi. Pour toute autre utilisation, une autorisation écrite des titulaires des droits d'auteur sera nécessaire.