Afficher la notice

dc.contributor.advisorGaron, André
dc.contributor.advisorCarrier, Michel
dc.contributor.authorNandlall, Ian
dc.date.accessioned2012-05-16T21:00:53Z
dc.date.availableNO_RESTRICTIONen
dc.date.available2012-05-16T21:00:53Z
dc.date.issued2012-05-03
dc.date.submitted2012-03
dc.identifier.urihttp://hdl.handle.net/1866/7124
dc.subjectSystème cardiovasculaireen
dc.subjectModélisation numériqueen
dc.subjectPompes d'assistance ventriculaireen
dc.subjectInsuffisance cardiaqueen
dc.subjectCardiovascular systemen
dc.subjectNumerical modelingen
dc.subjectVentricular assist devicesen
dc.subjectHeart failureen
dc.subject.otherEngineering - Biomedical / Ingénierie - Biomédicale (UMI : 0541)en
dc.titleÉvaluation in silico des pompes d’assistance ventriculaire de type écoulement mixteen
dc.typeThèse ou mémoire / Thesis or Dissertation
etd.degree.disciplineGénie biomédicalen
etd.degree.grantorUniversité de Montréalfr
etd.degree.levelMaîtrise / Master'sen
etd.degree.nameM. Sc. A.en
dcterms.abstractL'insuffisance cardiaque est une maladie à grande incidence dont le traitement définitif est difficile. Les pompes d'assistance ventriculaire ont été proposées comme thérapie alternative à long terme, mais la technologie est relativement jeune et selon son design, axial ou centrifuge, le dispositif favorise soit l'hémolyse, soit la stagnation de l'écoulement sanguin. Les pompes à écoulement mixte, combinant certaines propriétés des deux types, ont été proposées comme solution intermédiaire. Pour évaluer leurs performances, nous avons effectué des comparaisons numériques entre huit pompes, deux axiales, deux centrifuges, et quatre mixtes, en employant un modèle Windkessel du système cardiovasculaire avec paramètres optimisés pour l'insuffisance cardiaque résolu avec une méthode Radau IIA3, une méthode de résolution de système d'équations différentielles ordinaires L-stable appartenant à la famille des méthodes Runge-Kutta implicites. Nos résultats semblent suggérer que les pompes d'assistance mixtes ne démontrent qu'un léger avantage comparativement aux autres types en terme de performance optimale dans le cas de l'insuffisance cardiaque, mais il faudrait effectuer plus d'essais numériques avec un modèle plus complet, entre autres avec contrôles nerveux implémentés.en
dcterms.abstractHeart failure is a disease with a high incidence rate that is difficult to treat definitively. Ventricular assist devices have been proposed as alternative long-term therapeutic options, but the technology is fairly recent and depending on the design, axial or centrifugal, the device will favor hemolysis or blood flow stagnation. Mixed flow devices, which combine properties of the two previous types, have therefore been proposed as intermediate solutions. To evaluate their performance, we did a numerical comparison between eight pumps (two axial, two centrifugal, and four mixed) using a Windkessel model of the cardiovascular system with parameters optimised for heart failure and solved using a Radau IIA3 method, an L-stable method used to numerically solve systems of ordinary differential equations that belongs to the family of implicit Runge-Kutta methods. Our results suggest that in terms of optimal performance, mixed flow pumps are modest improvements over the other two types, and more tests would have to be performed using a more complete model with, among other modifications, neural control systems implemented.en
dcterms.languagefraen


Fichier·s constituant ce document

Vignette

Ce document figure dans la ou les collections suivantes

Afficher la notice

Ce document diffusé sur Papyrus est la propriété exclusive des titulaires des droits d'auteur et est protégé par la Loi sur le droit d'auteur (L.R.C. (1985), ch. C-42). Il peut être utilisé dans le cadre d'une utilisation équitable et non commerciale, à des fins d'étude privée ou de recherche, de critique ou de compte-rendu comme le prévoit la Loi. Pour toute autre utilisation, une autorisation écrite des titulaires des droits d'auteur sera nécessaire.