Show item record

dc.contributor.advisorSauvé, Sébastien
dc.contributor.advisorPrévost, Michèle
dc.contributor.authorLemoine, Pascal
dc.date.accessioned2010-11-15T17:37:17Z
dc.date.availableMONTHS_WITHHELD:12en
dc.date.available2010-11-15T17:37:17Z
dc.date.issued2010-10-07
dc.date.submitted2010-04
dc.identifier.urihttp://hdl.handle.net/1866/4265
dc.subjectLDTDen
dc.subjectAPCIen
dc.subjectMS/MSen
dc.subjectAnatoxine-aen
dc.subjectPhénylalanineen
dc.subjectCyanotoxineen
dc.subjectMicrocystineen
dc.subjectSaxitoxineen
dc.subjectCylindrospermopsineen
dc.subjectCyanobactérieen
dc.subjectAnatoxin-aen
dc.subjectPhenylalanineen
dc.subjectCyanotoxinen
dc.subjectMicrocystinen
dc.subjectSaxitoxinen
dc.subjectCylindrospermopsinen
dc.subjectCyanobacteriaen
dc.subject.otherChemistry - Analytical / Chimie analytique (UMI : 0486)en
dc.titleAnalyse quantitative des cyanotoxines d'eau douce par LDTD-APCI-MS/MSen
dc.typeThèse ou mémoire / Thesis or Dissertation
etd.degree.disciplineChimieen
etd.degree.grantorUniversité de Montréalfr
etd.degree.levelMaîtrise / Master'sen
etd.degree.nameM. Sc.en
dcterms.abstractAvec la hausse mondiale de la fréquence des floraisons de cyanobactéries (CB), dont certaines produisent des cyanotoxines (CT), le développement d’une méthode de détection/quantification rapide d’un maximum de CT s’impose. Cette méthode permettrait de faire un suivi quotidien de la toxicité de plans d’eau contaminés par des CB et ainsi d’émettre rapidement des avis d’alerte appropriés afin de protéger la santé publique. Une nouvelle technologie utilisant la désorption thermique induite par diode laser (LDTD) couplée à l’ionisation chimique sous pression atmosphérique (APCI) et reliée à la spectrométrie de masse en tandem (MS/MS) a déjà fait ses preuves avec des temps d'analyse de l’ordre de quelques secondes. Les analytes sont désorbés par la LDTD, ionisés en phase gazeuse par APCI et détectés par la MS/MS. Il n’y a donc pas de séparation chromatographique, et la préparation de l’échantillon avant l’analyse est minimale selon la complexité de la matrice contenant les analytes. Parmi les quatre CT testées (microcystine-LR, cylindrospermopsine, saxitoxine et anatoxine-a (ANA-a)), seule l’ANA-a a généré une désorption significative nécessaire au développement d’une méthode analytique avec l’interface LDTD-APCI. La forte polarité ou le poids moléculaire élevé des autres CT empêche probablement leur désorption. L’optimisation des paramètres instrumentaux, tout en tenant compte de l’interférence isobarique de l’acide aminé phénylalanine (PHE) lors de la détection de l’ANA-a par MS/MS, a généré une limite de détection d’ANA-a de l’ordre de 1 ug/L. Celle-ci a été évaluée à partir d’une matrice apparentée à une matrice réelle, démontrant qu’il serait possible d’utiliser la LDTD pour effectuer le suivi de l’ANA-a dans les eaux naturelles selon les normes environnementales applicables (1 à 12 ug/L). Il a été possible d’éviter l’interférence isobarique de la PHE en raison de sa très faible désorption avec l’interface LDTD-APCI. En effet, il a été démontré qu’une concentration aussi élevée que 500 ug/L de PHE ne causait aucune interférence sur le signal de l’ANA-a.en
dcterms.abstractWithin the context of the worldwide increasing frequency of cyanobacterial (CB) blooms, some containing cyanotoxins (CT), the development of a detection/quantification method for the fast analysis a maximum of CT is necessary. This method would allow daily tracking of the toxicity of CB-contaminated water such that, as warranted, appropriate measures can be taken quickly to protect public health. A new technology using laser diode thermal desorption (LDTD) coupled to atmospheric pressure chemical ionization (APCI)-tandem mass spectrometry (MS/MS) has shown great potential to reduce analysis time to seconds. Analytes are desorbed by the LDTD, ionized in gas-phase by APCI and detected by MS/MS. Therefore, there is no chromatographic separation and sample treatment prior to analysis is minimal, depending on the complexity of the sample matrix. Among the four CT tested (microcystin-LR, cylindrospermopsin, saxitoxin and anatoxin-a (ANA-a)), only ANA-a exhibited sufficient desorption which is necessary to develop an analytical method with the LDTD-APCI interface. The strong polarity or high molecular weight of the other CT probably inhibited their efficient desorption. Optimization of instrumental parameters, while accounting for the isobaric interference caused by the acid amino phenylalanine (PHE) in the detection of ANA-a by MS/MS, generated a detection limit of the order of 1 ug/L ANA-a. This value was obtained in a simulated natural matrix, demonstrating that it would be possible to use LDTD to monitor ANA-a in natural waters within the range of current applicable environmental guidelines (1 to 12 ug/L). Because PHE desorption is limited with the LDTD-APCI interface, this method avoids its interference on ANA-a analysis, even at PHE concentrations as high as 500 ug/L.en
dcterms.languagefraen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show item record

This document disseminated on Papyrus is the exclusive property of the copyright holders and is protected by the Copyright Act (R.S.C. 1985, c. C-42). It may be used for fair dealing and non-commercial purposes, for private study or research, criticism and review as provided by law. For any other use, written authorization from the copyright holders is required.