Afficher la notice

dc.contributor.advisorSoulez, Gilles
dc.contributor.advisorMartel, Sylvain
dc.contributor.authorDimov, Ivan Petrov
dc.date.accessioned2023-09-18T18:38:39Z
dc.date.availableNO_RESTRICTIONfr
dc.date.available2023-09-18T18:38:39Z
dc.date.issued2023-08-07
dc.date.submitted2023-04
dc.identifier.urihttp://hdl.handle.net/1866/28740
dc.subjectAngiographie par résonance magnétiquefr
dc.subjectHémodynamiefr
dc.subjectCirculation hépatiquefr
dc.subjectCirculation splanchniquefr
dc.subjectImagerie tridimensionnellefr
dc.subject4D flowfr
dc.subjectMRI angiographyfr
dc.subjectHemodynamicsfr
dc.subjectHepatic circulationfr
dc.subjectSplanchnic circulationfr
dc.subjectThree-dimensional imagingfr
dc.subject.otherMedical imaging / Imagerie médicale (UMI : 0574)fr
dc.titleLa caractérisation du flux artériel hépatique par la technique 4D Flowfr
dc.typeThèse ou mémoire / Thesis or Dissertation
etd.degree.disciplineSciences biomédicalesfr
etd.degree.grantorUniversité de Montréalfr
etd.degree.levelMaîtrise / Master'sfr
etd.degree.nameM. Sc.fr
dcterms.abstractObjectif : Déterminer la capacité de la séquence IRM 4D flow à mesurer la forme et le flot (débit, vélocité) de l’artère hépatique et de ses branches en trois dimensions. Méthodologie : Un fantôme de l’artère hépatique réaliste qui imite le flux sanguin et les mouvements respiratoires ainsi que 20 volontaires ont été imagés. La précision du 4D flow Cartésien avec navigateur et remplissage de l’espace-k selon la position respiratoire était déterminée in-vitro à quatre résolutions spatiales (0,5 à 1,0 mm isotropique) et fenêtres d’acceptation du navigateur (± 8 et ± 2 mm) avec un scanner IRM à 3T. Deux séquences centrées sur les branches hépatiques et gastroduodénales étaient évaluées in-vivo et comparés au contraste de phase 2D. Résultats : In vitro, l’augmentation de la résolution spatiale diminuait plus l’erreur qu’une fenêtre d’acceptation plus étroite (30.5 à -4.67% vs -6.64 à -4.67% pour le débit). In vivo, les artèreshépatiques et gastroduodénales étaient mieux visualisées avec la séquence de haute résolution (90 vs 71%). Malgré un accord interobservateur similaire (κ = 0.660 et 0.704), la séquence à plus haute résolution avait moins de variabilité pour l’aire, le débit, et la vélocité moyenne. Le 4D flow avait une meilleure cohérence interne entre l’afflux et l’efflux à la bifurcation de l’artère hépatique (1.03 ± 5.05% et 15.69 ± 6.14%) que le contraste de phase 2D (28.77 ± 21.01%). Conclusion : Le 4D flow à haute résolution peut évaluer l’anatomie et l’hémodynamie de l’artère hépatique avec une meilleure précision, visibilité, moindre variabilité et meilleure concordance interne.fr
dcterms.abstractObjectives: To assess the ability of four-dimensional (4D) flow, an MRI sequence that captures the form and flow of vessels in three dimensions, to measure hepatic arterial hemodynamics. Methods: A dynamic hepatic artery phantom and 20 consecutive volunteers were scanned. The accuracies of Cartesian 4D flow sequences with k-space reordering and navigator gating at four spatial resolutions (0.5- to 1-mm isotropic) and navigator acceptance windows (± 8 to ± 2 mm) were assessed in vitro at 3 T. Two sequences centered on gastroduodenal and hepatic artery branches were assessed in vivo for intra - and interobserver agreement and compared to 2D phase-contrast (0.5-mm in -plane). Results In vitro, higher spatial resolution led to a greater decrease in error than narrower navigator window (30.5 to −4.67% vs−6.64 to −4.67% for flow). In vivo, hepatic and gastroduodenal arteries were visualized more frequently with the higher resolution sequence (90 vs 71%). Despite similar interobserver agreement (κ = 0.660 and 0.704), the higher resolution sequence had lower variability for area, flow, and average velocity. 4D flow had lower differences between inflow and outflow at the hepatic artery bifurcation (11.03 ± 5.05% and 15.69 ± 6.14%) than 2D phase-contrast (28.77 ± 21.01%). Conclusion: High-resolution 4D flow can assess hepatic artery anatomy and hemodynamics with improved accuracy, greater vessel visibility, better interobserver reliability, and internal consistency.fr
dcterms.languagefrafr
UdeM.ORCIDAuteurThese0000-0003-4405-1718fr


Fichier·s constituant ce document

Vignette

Ce document figure dans la ou les collections suivantes

Afficher la notice

Ce document diffusé sur Papyrus est la propriété exclusive des titulaires des droits d'auteur et est protégé par la Loi sur le droit d'auteur (L.R.C. (1985), ch. C-42). Il peut être utilisé dans le cadre d'une utilisation équitable et non commerciale, à des fins d'étude privée ou de recherche, de critique ou de compte-rendu comme le prévoit la Loi. Pour toute autre utilisation, une autorisation écrite des titulaires des droits d'auteur sera nécessaire.