Show item record

dc.contributor.advisorHarel, François
dc.contributor.authorOlamaei, Nina
dc.date.accessioned2009-06-02T16:42:09Z
dc.date.availableNO_RESTRICTIONen
dc.date.available2009-06-02T16:42:09Z
dc.date.issued2009-04-16
dc.date.submitted2009-01
dc.identifier.urihttp://hdl.handle.net/1866/2854
dc.subjectReactive hyperemiaen
dc.subjectHyperémie réactiveen
dc.subjectMyogenic responseen
dc.subjectRéponse myogéniqueen
dc.subjectAtherosclerosisen
dc.subjectAthéroscléroseen
dc.subjectNitric oxideen
dc.subjectOxyde nitriqueen
dc.subjectNear infrared spectroscopyen
dc.subjectSpectroscopie proche infrarougeen
dc.subject.otherEngineering - Biomedical / Ingénierie - Biomédicale (UMI : 0541)en
dc.titleReactive Hyperemia as endothelial function determinant using plethysmography methodsen
dc.typeThèse ou mémoire / Thesis or Dissertation
etd.degree.disciplineGénie biomédicalen
etd.degree.grantorUniversité de Montréalfr
etd.degree.levelMaîtrise / Master'sen
etd.degree.nameM. Sc. A.en
dcterms.abstractL’atteinte de la fonction endothéliale représente une phase précoce de l’athérosclérose, un stade où les patients sont généralement asymptomatiques. Il existe donc un intérêt certain à détecter la dysfonction endothéliale. Nous avons développé une technique de mesure des variations de flot artériel au niveau des membres supérieurs, basée sur la spectroscopie proche infrarouge (NIRS). Cette approche permettrait d’étudier le niveau d’atteinte vasculaire et probablement de quantifier le degré de dysfonction endothéliale périphérique lors d’une hyperémie réactive. L'expérience a été exécutée sur deux cohortes de 13 et de 15 patients et a été comparée à la pléthysmographie par jauge de contrainte (SGP) qui est considérée comme une méthode de référence. Par la suite, nous avons caractérisé la réponse endothéliale par modélisation de la courbe hyperémique du flot artériel. Des études préliminaires avaient démontré que la réponse hyperémique adoptait majoritairement une forme bi-modale. Nous avons tenté de séparer les composantes endothéliales-dépendantes et endothéliales-indépendantes de l’hyperémie. La quantification des deux composantes de la réaction hyperémique permet de calculer un indice de la ‘santé’ du système endothélial local. Cet indice est nommé le ηfactor. Les résultats montrent une forte corrélation des mesures de flots entre la technique développée et la méthode de référence (r=0.91). Nous avons conclu que NIRS est une approche précise pour la mesure non-invasive du flot artériel. Nous avons obtenu une bonne répétabilité (ICC = 0.9313) pour le ηfactor indiquant sa robustesse. Cependant des études supplémentaires sont nécessaires pour valider la valeur de diagnostic du facteur défini. Mots clés: hyperémie réactive, réponse myogénique, oxyde nitrique, athérosclérose, spectroscopie proche infrarougeen
dcterms.abstractAtherosclerotic diseases are mainly caused by coronary and peripheral blood vessel disorders. Endothelial dysfunction represents an early phase in these diseases, when patients are generally asymptomatic. We developed a technique, based on near infrared spectroscopy (NIRS), for measurement of arterial blood flow variations in limbs during reactive hyperemia. The technique allows the study of the level of vascular impairment and probably quantifying the level of endothelial dysfunction at peripheral arteries. The experiment was performed on two cohorts of 13 and 15 patients and was compared to strain gauge plethysmography (SGP) which is considered as gold standard. Afterward, we characterized endothelial reaction during reactive hyperemia through blood flow variations by modeling the hyperemic curve. Preliminary studies have shown that the hyperemic response generally adopts a bimodal form. The first peak was attributed to myogenic reaction that is endothelial independent and the second one to local endothelial cells reaction. The quantification of the two hyperemic response components makes it possible to calculate an index of ‘health’ for local endothelial cells, named ηfactor. The results showed a strong correlation (r = 0.91) of blood flow measurements between the developed method and the gold standard. We concluded that NIRS is a precise technique for non-invasive measurement of blood flow. Moreover, we found a high repeatability (ICC = 0.9313) of the ηfactor in repeated measurements indicating its robustness. Nonetheless, more studies are required to validate the diagnosis value of the defined factor. Key words: reactive hyperemia, myogenic response, endothelial dependent vasodilatation, nitric oxide, atherosclerosis, near infrared spectroscopy (NIRS)en
dcterms.languageengen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show item record

This document disseminated on Papyrus is the exclusive property of the copyright holders and is protected by the Copyright Act (R.S.C. 1985, c. C-42). It may be used for fair dealing and non-commercial purposes, for private study or research, criticism and review as provided by law. For any other use, written authorization from the copyright holders is required.