Show item record

dc.contributor.advisorJacquemet, Vincent
dc.contributor.authorSaha, Mirabeau
dc.date.accessioned2016-05-25T18:10:13Z
dc.date.availableNO_RESTRICTIONfr
dc.date.available2016-05-25T18:10:13Z
dc.date.issued2016-05-12
dc.date.submitted2015-11
dc.identifier.urihttp://hdl.handle.net/1866/13896
dc.subjectFibrillation auriculairefr
dc.subjectModélisation mathématiquefr
dc.subjectAblation par cathéterfr
dc.subjectReconnexion des lignes d’ablationfr
dc.subjectOnde Pfr
dc.subjectÉlectrocardiogrammefr
dc.subjectAtrial fibrillationfr
dc.subjectMathematical modelingfr
dc.subjectCatheter ablationfr
dc.subjectAblation lines reconnectionfr
dc.subjectP wavefr
dc.subjectElectrocardiogramfr
dc.subject.otherEngineering - Biomedical / Ingénierie - Biomédicale (UMI : 0541)fr
dc.titleModélisation de l’activité électrique des oreillettes avant et après ablation par cathéterfr
dc.typeThèse ou mémoire / Thesis or Dissertation
etd.degree.disciplineGénie biomédicalfr
etd.degree.grantorUniversité de Montréalfr
etd.degree.levelMaîtrise / Master'sfr
etd.degree.nameM. Sc. A.fr
dcterms.abstractLa fibrillation auriculaire (FA) est la forme d’arythmie la plus fréquente chez les êtres humains. Les mécanismes qui gouvernent l’initiation et les manifestations de cette maladie sont complexes, de nature dynamique, incluant des interactions à travers multiples échelles temporelles et spatiales dans les oreillettes. Ceci conduit très souvent à des manifestations imprévisibles et à des phénomènes qui émergent à l’échelle de l’organe, et qui se reflètent à l’échelle de tout le torse. Pour remédier à ce problème, on peut effectuer une ablation par cathéter, qui consiste à créer sur le tissu auriculaire des lésions linéaires qui bloquent et contraignent la propagation électrique. Parfois, ces lignes se reconnectent quelque temps après l’intervention, ce qui mène à des récidives, nécessitant ainsi une nouvelle intervention. Le but de ce projet est de modéliser un suivi de l’onde P post-opératoire pour détecter de manière non-invasive la reconnexion des lignes d’ablation et ainsi prédire les récidives de fibrillation auriculaire. À l’aide d’un modèle mathématique des oreillettes et du thorax, les ondes P sont simulées avant et après ablation, ainsi qu’après reconnexion de certaines lignes d’ablation. Les résultats montrent que la morphologie et les caractéristiques de l’onde P, ainsi que la carte d’activation sont affectées significativement par l’ablation et les reconnexions subséquentes. Ces différences sont plus facilement détectables lorsque les reconnexions naissent sur la veine pulmonaire inférieure gauche. Les changements sont plus importants pour les électrodes placées sur certaines zones du torse, notamment dans le dos. Ces nouvelles données aident actuellement à la conception d’une étude clinique pour valider l’approche.fr
dcterms.abstractAtrial fibrillation (AF) is the most common form of arrhythmia in humans. The mechanisms governing the initiation and manifestations of that disease are complex, dynamic in nature, including interactions across multiple spatial and temporal scales in the atria. This often leads to unpredictable manifestations and phenomena that arise at the level of the organ, and are reflected across the entire torso. To remedy that problem, catheter ablation can be carried out, which consists in creating linear lesions which block and force the electrical propagation in the atrial tissue. Sometimes these lines reconnect after the procedure, which leads to atrial fibrillation recurrence, thus requiring a new intervention. The purpose of this work is to model the monitoring of the postoperative P wave to detect non-invasively the reconnection of ablation lines and to predict atrial fibrillation recurrences. Using a mathematical model of the atria and thorax, the P waves are simulated before and after ablation, as well as after reconnection of some ablation lines. The results show that the morphology and the characteristics of the P wave as well as the activation map are significantly affected by the ablation lines and the subsequent reconnections. These differences are more easily detected when reconnections arise on the left inferior pulmonary vein. The changes are most important in electrodes placed in certain areas of the torso, notably in the back. These new data are helping to plan a clinical study to validate the approach.fr
dcterms.description- Réalisé au centre de recherche de l'hospital du Sacré-Coeur de Montréal. - Programme conjoint entre Université de Montréal et École Polytechnique de Montréal.fr
dcterms.languagefrafr


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show item record

This document disseminated on Papyrus is the exclusive property of the copyright holders and is protected by the Copyright Act (R.S.C. 1985, c. C-42). It may be used for fair dealing and non-commercial purposes, for private study or research, criticism and review as provided by law. For any other use, written authorization from the copyright holders is required.