Show item record

dc.contributor.advisorCarrier, Jean-François
dc.contributor.advisorDe Guise, Jacques
dc.contributor.authorBesnier, Magali
dc.date.accessioned2015-10-26T16:22:19Z
dc.date.availableNO_RESTRICTIONfr
dc.date.available2015-10-26T16:22:19Z
dc.date.issued2015-09-23
dc.date.submitted2014-11
dc.identifier.urihttp://hdl.handle.net/1866/12452
dc.subjectTomodensitométriefr
dc.subjectDECTfr
dc.subjectsegmentationfr
dc.subjectrein fonctionnelfr
dc.subjectradiothérapiefr
dc.subjectorganes à risquefr
dc.subjectFunctionnal kidneyfr
dc.subjectComputed tomographyfr
dc.subjectradiotherapyfr
dc.subject.otherPhysics - Radiation / Physique - Radiation (UMI : 0756)fr
dc.titleSegmentation du rein fonctionnel à partir de CTdouble énergie injectésfr
dc.typeThèse ou mémoire / Thesis or Dissertation
etd.degree.disciplinePhysiquefr
etd.degree.grantorUniversité de Montréalfr
etd.degree.levelMaîtrise / Master'sfr
etd.degree.nameM. Sc.fr
dcterms.abstractLes néphropaties (maladie des tissus rénaux) postradiques constituent l'un des facteurs limitants pour l'élaboration des plans de traitement lors des radiothérapies abdominales. Le processus actuel, qui consiste à évaluer la fonctionnalité relative des reins grâce à une scintigraphie gamma deux dimensions, ne permet pas d'identifier les portions fonctionnelles qui pourraient être évitées lors de l' élaboration des plans de traitement. Une méthode permettant de cartographier la fonctionnalité rénale en trois dimensions et d'extraire un contour fonctionnel utilisable lors de la planification a été développée à partir de CT double énergie injectés à l'iode. La concentration en produit de contraste est considérée reliée à la fonctionnalité rénale. La technique utilisée repose sur la décomposition à trois matériaux permettant de reconstruire des images en concentration d'iode. Un algorithme de segmentation semi-automatisé basé sur la déformation hiérarchique et anamorphique de surfaces permet ensuite d'extraire le contour fonctionnel des reins. Les premiers résultats obtenus avec des images patient démontrent qu'une utilisation en clinique est envisageable et pourra être bénéfique.fr
dcterms.abstractPost-radic nephroaties (illness of kidney tissues) are one of the limitating factors when realising treatment planning for abdominal radiotherapies. The present process which consists in evaluating the Differential Kidney Function with a two-dimensional gamma scintigraphy, does not allow any identification of functional parts that could be taken into account during planification. The method presented in this document gives a three dimensional functional map of the kidney and a functional contour usable in planification, using double energy CT images with iodine contrast agent.The concentration in contrast agent is assumed to be related to kidney function. The proposed method is based on a three-materials decomposition allowing to reconstruct images of iodine concentration. The functionnal contour is extracted through a semi-automatic algorithm based on hierarchic and anamorphic surface deformation. First results obtained with patient images demonstrate the possibility of several future clinical applications.fr
dcterms.languagefrafr


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show item record

This document disseminated on Papyrus is the exclusive property of the copyright holders and is protected by the Copyright Act (R.S.C. 1985, c. C-42). It may be used for fair dealing and non-commercial purposes, for private study or research, criticism and review as provided by law. For any other use, written authorization from the copyright holders is required.