dc.titleActivity monitor placed at the non-paretic ankle is accurate in measuring step counts during community walking in post-stroke individuals : a validation studyfr
dc.typeArticlefr
dc.contributor.affiliationUniversité de Montréal. Faculté de médecine. École de réadaptationfr
dc.identifier.doi10.1002/pmrj.12080
dcterms.abstractBackground: Different environmental factors may affect the accuracy of step-count activity monitors (AM). However, the validationconditions for AM accuracy largely differ from ecological environments.Objectives: To assess and compare the accuracy of AM in counting steps among poststroke individuals: during different locomotortasks, with AM placed at the nonparetic ankle or hip, and when walking in a laboratory or inside a mall.Design: Validation study.Settings: Laboratory and community settings.Participants: Twenty persons with chronic hemiparesis, independent walkers.Methods: First session: participants performed level walking (6-minute walk test [6MWT]), ramps, and stairs in the laboratory withAM placed at the nonparetic ankle and hip. Second session: participants walked a mall circuit, including the three tasks, with AMplaced at the nonparetic ankle. The sessions were video recorded.Main Outcome Measurements: Absolute difference between the steps counted by AM and the steps viewed on the video recordings(errors, %); occurrence of errors greater than 10%.Results: Median errors were similar for the 6MWT (0.86 [0.22, 7.70]%), ramps (2.17 [0.89, 9.61]%), and stairs (8.33 [2.65, 19.22]%)with AM at the ankle. Step-count error was lower when AM was placed at the ankle (8.33 [ 2.65, 19.22]%) than at the hip (9.26[3.25, 42.63]%, P = .03). The greatest errors were observed among the slowest participants (≤0.4 m/s) on ramps and stairs, whereassome faster participants (>1 m/s) experienced the greatest error during the 6MWT. Median error was slightly increased in the mallcircuit (2.67 [0.61, 12.54]%) compared with the 6MWT (0.50 [0.24, 6.79]%, P = .04), with more participants showing errors >10% dur-ing the circuit (7 vs 2, P = .05).Conclusions: Step counts are accurately measured with AM placed at the nonparetic ankle in laboratory and community settings.Accuracy can be altered by stairs and ramps among the slowest walkers and by prolonged walking tasks among faster walkers.Level of Evidence: III .fr
dcterms.isPartOfurn:ISSN:1934-1482fr
dcterms.languageengfr
UdeM.ReferenceFournieParDeposant10.1002/pmrj.12080fr
UdeM.VersionRioxxVersion acceptée / Accepted Manuscriptfr
oaire.citationTitlePM&Rfr
oaire.citationVolume11fr
oaire.citationIssue9fr
oaire.citationStartPage963fr
oaire.citationEndPage971fr


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show item record

This document disseminated on Papyrus is the exclusive property of the copyright holders and is protected by the Copyright Act (R.S.C. 1985, c. C-42). It may be used for fair dealing and non-commercial purposes, for private study or research, criticism and review as provided by law. For any other use, written authorization from the copyright holders is required.