Show item record

dc.contributor.advisorJacquemet, Vincent
dc.contributor.authorSabouri, Sepideh
dc.date.accessioned2014-01-17T17:15:34Z
dc.date.availableNO_RESTRICTIONfr
dc.date.available2014-01-17T17:15:34Z
dc.date.issued2013-11-07
dc.date.submitted2013-05
dc.identifier.urihttp://hdl.handle.net/1866/10273
dc.subjectCantact cartographie épicardiquefr
dc.subjectNoncontact cartographie endocavitairefr
dc.subjectLa fibrillation auriculairefr
dc.subjectCathéter à ballonnetfr
dc.subjectModèle informatique cardiaquefr
dc.subjectCantact epicardial mappingfr
dc.subjectNoncontact endocardial mappingfr
dc.subjectAtrial fibrillationfr
dc.subjectBalloon catheterfr
dc.subjectCardiac computer modelfr
dc.subject.otherEngineering - Biomedical / Ingénierie - Biomédicale (UMI : 0541)fr
dc.titleComparison of epicardial mapping and noncontact endocardial mapping in dog experiments and computer simulationsfr
dc.typeThèse ou mémoire / Thesis or Dissertation
etd.degree.disciplineGénie biomédicalfr
etd.degree.grantorUniversité de Montréalfr
etd.degree.levelMaîtrise / Master'sfr
etd.degree.nameM. Sc.fr
dcterms.abstractLa fibrillation auriculaire, l'arythmie la plus fréquente en clinique, affecte 2.3 millions de patients en Amérique du Nord. Pour en étudier les mécanismes et les thérapies potentielles, des modèles animaux de fibrillation auriculaire ont été développés. La cartographie électrique épicardique à haute densité est une technique expérimentale bien établie pour suivre in vivo l'activité des oreillettes en réponse à une stimulation électrique, à du remodelage, à des arythmies ou à une modulation du système nerveux autonome. Dans les régions qui ne sont pas accessibles par cartographie épicardique, la cartographie endocardique sans contact réalisée à l'aide d'un cathéter en forme de ballon pourrait apporter une description plus complète de l'activité auriculaire. Dans cette étude, une expérience chez le chien a été conçue et analysée. Une reconstruction électro-anatomique, une cartographie épicardique (103 électrodes), une cartographie endocardique sans contact (2048 électrodes virtuelles calculées à partir un cathéter en forme de ballon avec 64 canaux) et des enregistrements endocardiques avec contact direct ont été réalisés simultanément. Les systèmes d'enregistrement ont été également simulés dans un modèle mathématique d'une oreillette droite de chien. Dans les simulations et les expériences (après la suppression du nœud atrio-ventriculaire), des cartes d'activation ont été calculées pendant le rythme sinusal. La repolarisation a été évaluée en mesurant l'aire sous l'onde T auriculaire (ATa) qui est un marqueur de gradient de repolarisation. Les résultats montrent un coefficient de corrélation épicardique-endocardique de 0.8 (expérience) and 0.96 (simulation) entre les cartes d'activation, et un coefficient de corrélation de 0.57 (expérience) and 0.92 (simulation) entre les valeurs de ATa. La cartographie endocardique sans contact apparait comme un instrument expérimental utile pour extraire de l'information en dehors des régions couvertes par les plaques d'enregistrement épicardique.fr
dcterms.abstractAtrial fibrillation is the most common clinical arrhythmia currently affecting 2.3 million patients in North America. To study its mechanisms and potential therapies, animal models of atrial fibrillation have been developed. Epicardial high-density electrical mapping is a well-established experimental instrument to monitor in vivo the activity of the atria in response to pacing, remodeling, arrhythmias and modulation of the autonomic nervous system. In regions that are not accessible by epicardial mapping, noncontact endocardial mapping performed through a balloon catheter may provide a more comprehensive description of atrial activity. In this study, a dog experiment was designed and analyzed in which electroanatomical reconstruction, epicardial mapping (103 electrodes), noncontact endocardial mapping (2048 virtual electrodes computed from a 64-channel balloon catheter), and direct-contact endocardial catheter recordings were simultaneously performed. The recording system was also simulated in a computer model of the canine right atrium. For simulations and experiments (after atrio-ventricular node suppression), activation maps were computed during sinus rhythm. Repolarization was assessed by measuring the area under the atrial T wave (ATa), a marker of repolarization gradients. Results showed an epicardial endocardial correlation coefficient of 0.8 (experiment) and 0.96 (simulation) between activation times, and a correlation coefficient of 0.57 (experiment) and 0.92 (simulation) between ATa values. Noncontact mapping appears to be a valuable experimental device to retrieve information outside the regions covered by epicardial recording plaques.fr
dcterms.languageengfr


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show item record

This document disseminated on Papyrus is the exclusive property of the copyright holders and is protected by the Copyright Act (R.S.C. 1985, c. C-42). It may be used for fair dealing and non-commercial purposes, for private study or research, criticism and review as provided by law. For any other use, written authorization from the copyright holders is required.