Afficher la notice

dc.contributor.advisorSchmittbuhl, Matthieu
dc.contributor.authorBenaim, Eliyahou
dc.date.accessioned2023-11-23T19:12:30Z
dc.date.availableNO_RESTRICTIONfr
dc.date.available2023-11-23T19:12:30Z
dc.date.issued2023-10-21
dc.date.submitted2023-03
dc.identifier.urihttp://hdl.handle.net/1866/32090
dc.subjectCBCTfr
dc.subjectRéduction de la dosefr
dc.subjectReconstruction itérativefr
dc.subjectCanine inclusefr
dc.subjectOrthodontiefr
dc.subjectDose reductionfr
dc.subjectIterative reconstructionfr
dc.subjectImpacted caninefr
dc.subjectOrthodonticsfr
dc.subject.otherDentistry / Médecine dentaire (UMI : 0567)fr
dc.titleValidation des modalités d’imagerie CBCT basse dose dans les bilans de localisation des canines inclusesfr
dc.typeThèse ou mémoire / Thesis or Dissertation
etd.degree.disciplineMédecine dentairefr
etd.degree.grantorUniversité de Montréalfr
etd.degree.levelMaîtrise / Master'sfr
etd.degree.nameM. Sc.fr
dcterms.abstractOBJECTIF : L’objectif de cette étude a été de valider le potentiel des méthodes de reconstruction itérative nouvellement développées en imageries CT à faisceau conique, afin de réduire la dose d’exposition dans le cadre des bilans de localisation des canines incluses. MÉTHODOLOGIE : Quarante examens par imagerie volumétrique à faisceau conique de canines incluses ont été reconstruits à pleine dose (D), demi-dose (D2) et quart de dose (D4). Ces examens ont été analysés par un radiologiste maxillo-facial et par un résident en orthodontie. La cohérence entre les évaluations des critères radiologiques retenus a été évaluée avec les tests de Kappa Cohen. RÉSULTATS : Les résultats de cette étude ont montré de fortes valeurs de Kappa concernant l'évaluation inter-examinateur de la position de la canine impactée avec des scores compris entre 0.606 – 0.839. Les valeurs de Kappa déterminées pour la résorption, l'ankylose et les lésions associées étaient beaucoup plus faibles avec des scores compris entre 0.000 et 0.529. CONCLUSION : Cette étude a permis de montrer que la localisation des canines incluses pourrait potentiellement être possible à faible dose (1/4 dose), comparativement à un dosage conventionnel. Toutefois, le diagnostic de la résorption, de l'ankylose ou encore de certaines lésions associées nécessitent de la haute résolution et donc des acquisitions à pleine dose.fr
dcterms.abstractAIM : The aim of this study was to validate the potential of newly developed iterative reconstruction methods in cone beam CT imaging to reduce the exposure dose for localization assessments of impacted canines. METHODS : Forty Cone beam CT examinations of impacted canines were reconstructed at full dose (D), half dose (D2) and quarter dose (D4). These examinations were analyzed by a maxillofacial radiologist and by an orthodontic resident. Consistency between the assessments of the selected radiological criteria was evaluated with Kappa Cohen tests. RESULTS : The results of this study showed high Kappa values regarding the inter-examiner assessment of the impacted canine position with scores ranging from 0.606 - 0.839. The Kappa values determined for resorption, ankylosis and associated lesions were lower with scores between 0.000 and 0.529. CONCLUSION : This study showed that the localization of impacted canines could potentially be possible at low dose (1/4 dose), compared to a conventional assay. However, the diagnosis of resorption, ankylosis or certain associated lesions requires high resolution and therefore full dose acquisitions.fr
dcterms.languagefrafr


Fichier·s constituant ce document

Vignette

Ce document figure dans la ou les collections suivantes

Afficher la notice

Ce document diffusé sur Papyrus est la propriété exclusive des titulaires des droits d'auteur et est protégé par la Loi sur le droit d'auteur (L.R.C. (1985), ch. C-42). Il peut être utilisé dans le cadre d'une utilisation équitable et non commerciale, à des fins d'étude privée ou de recherche, de critique ou de compte-rendu comme le prévoit la Loi. Pour toute autre utilisation, une autorisation écrite des titulaires des droits d'auteur sera nécessaire.