Afficher la notice

dc.contributor.advisorCarrier, Jean-François
dc.contributor.advisorBedwani, Stéphane
dc.contributor.authorLaplante, Caroline
dc.date.accessioned2022-04-19T19:49:02Z
dc.date.availableNO_RESTRICTIONfr
dc.date.available2022-04-19T19:49:02Z
dc.date.issued2022-03-16
dc.date.submitted2021-08
dc.identifier.urihttp://hdl.handle.net/1866/26562
dc.subjectfonction pulmonairefr
dc.subjectCT 4Dfr
dc.subjecttomodensitométriefr
dc.subjectradiothérapiefr
dc.subjectrecalage déformablefr
dc.subjectSPECTfr
dc.subjectventilation pulmonairefr
dc.subjectcomputed tomographyfr
dc.subjectpulmonary functionfr
dc.subjectradiotherapyfr
dc.subjectdeformable image registrationfr
dc.subject.otherPhysics - Theory / Physique - Théorie (UMI : 0753)fr
dc.titleValidation de la ventilation pulmonaire par recalage déformable des images de tomodensitométrie 4Dfr
dc.typeThèse ou mémoire / Thesis or Dissertation
etd.degree.disciplinePhysiquefr
etd.degree.grantorUniversité de Montréalfr
etd.degree.levelMaîtrise / Master'sfr
etd.degree.nameM. Sc.fr
dcterms.abstractL’évaluation de la fonction pulmonaire est important pour la réduction des complications radio-induites des traitements de radiothérapie. En effet, plus de 30% des patients souffriront de pneumonie des suites de leur traitement [1]. L’implantation de la fonction pulmonaire dans la planification de traitement pourrait limiter les complications médicales. La ventilation pulmonaire, l’une des deux métriques permettant de caractériser la fonction pulmonaire, est habituellement obtenue à partir de mesures SPECT. Cependant, cette méthode demande d’effectuer des acquisitions de mesure supplémentaires sur les patients. L’objectif de ce projet est de valider l’utilisation de CT 4D afin d’extraire la ventilation pulmonaire. La preuve de concept a été effectuée sur une cohorte de 25 patients atteints de cancer du poumon. Grâce à des recalages déformables effectués à l’aide du logiciel ANTs, la ventilation a été extraite. Les valeurs obtenues ont été comparées à celles déterminées à partir des données de SPECT, analysées par un logiciel clinique nommé Hermès. Une corrélation modérée a été observée, avec un coefficient de Pearson de r =0:59 avec p<0:05. Les valeurs de ventilation obtenues par CT 4D ont été validées par les coefficients de Dice (DC > 0:9), la distance de Hausdorff (HD < 2 mm), le positionnement de marqueurs anatomiques et les valeurs de jacobien des transformations. Des incertitudes provenant de l’acquisition de données et l’initialisation des paramètres des recalages déformables peuvent expliquer ces résultats.fr
dcterms.abstractThe assessment of pulmonary functionality is of prime importance to avoid radioinduced complications after radiotherapy treatments of lung cancer. Indeed, more than 30% of patients will suffer from a radiation-induced pneumonia following the treatment [1]. Implementing functionality in treatment planning could limit the medical complications. The current community standard for measuring the ventilation - one of the two metrics concerning pulmonary functionality - is SPECT imaging. However, this method requires to perform additional image acquisitions on patients. The objective of this work is to validate an image analysis method that provides deformable image registration allowing us to estimate lung ventilation for each voxel with four-dimensional computed tomography imaging (4DCT). The proof of concept is performed on a cohort of 25 patients with lung cancer. Each patient is required to a 4DCT scan before their radiotherapy treatment. Those scans were processed retroactively with Advanced Normalized Tools (ANTs) registration to evaluate the lungs deformation between the respiratory maxima. A vector field representing the deformation is produced for all voxels. Local behavior is estimated by the Jacobian of those vector fields. The deformation allows us to estimate the lung capacity to contain air, which can be linked to the ventilation. We showed that the values obtained with the 4DCT method are moderately correlated with those obtained by SPECT (r = 0:59; p < 0:05).Those results were validated using Dice coefficients (DC > 0:9), Hausdorff distance (HD < 2 mm) and targets registration error. The results of the lung ventilation obtained by 4DCT and with SPECT scans are moderately correlated. The uncertainties pertaining to data acquisition and deformable registration initialization might explain those differences.fr
dcterms.languagefrafr


Fichier·s constituant ce document

Vignette

Ce document figure dans la ou les collections suivantes

Afficher la notice

Ce document diffusé sur Papyrus est la propriété exclusive des titulaires des droits d'auteur et est protégé par la Loi sur le droit d'auteur (L.R.C. (1985), ch. C-42). Il peut être utilisé dans le cadre d'une utilisation équitable et non commerciale, à des fins d'étude privée ou de recherche, de critique ou de compte-rendu comme le prévoit la Loi. Pour toute autre utilisation, une autorisation écrite des titulaires des droits d'auteur sera nécessaire.