Afficher la notice

dc.contributor.advisorHoge, Richard
dc.contributor.authorTiret, Brice
dc.date.accessioned2014-01-17T20:37:59Z
dc.date.availableNO_RESTRICTIONfr
dc.date.available2014-01-17T20:37:59Z
dc.date.issued2013-11-07
dc.date.submitted2013-09
dc.identifier.urihttp://hdl.handle.net/1866/10296
dc.subjectMRIfr
dc.subjectSpectroscopyfr
dc.subjectPhosphorusfr
dc.subjectMetabolismfr
dc.subjectCoilfr
dc.subjectIRMfr
dc.subjectSpectroscopiefr
dc.subjectPhosphorefr
dc.subjectMétabolismefr
dc.subjectAntennefr
dc.subject.otherEngineering - Biomedical / Ingénierie - Biomédicale (UMI : 0541)fr
dc.titleIn vivo phosphorus spectroscopy in human subjects on a clinical 3T MRI systemfr
dc.typeThèse ou mémoire / Thesis or Dissertation
etd.degree.disciplineGénie biomédicalfr
etd.degree.grantorUniversité de Montréalfr
etd.degree.levelMaîtrise / Master'sfr
etd.degree.nameM. Sc. A.fr
dcterms.abstractAlors que l’Imagerie par résonance magnétique (IRM) permet d’obtenir un large éventail de données anatomiques et fonctionnelles, les scanneurs cliniques sont généralement restreints à l’utilisation du proton pour leurs images et leurs applications spectroscopiques. Le phosphore jouant un rôle prépondérant dans le métabolisme énergétique, l’utilisation de cet atome en spectroscopie RM présente un énorme avantage dans l’observation du corps humain. Cela représente un certain nombre de déEis techniques à relever dus à la faible concentration de phosphore et sa fréquence de résonance différente. L’objectif de ce projet a été de développer la capacité à réaliser des expériences de spectroscopie phosphore sur un scanneur IRM clinique de 3 Tesla. Nous présentons ici les différentes étapes nécessaires à la conception et la validation d’une antenne IRM syntonisée à la fréquence du phosphore. Nous présentons aussi l’information relative à réalisation de fantômes utilisés dans les tests de validation et la calibration. Finalement, nous présentons les résultats préliminaires d’acquisitions spectroscopiques sur un muscle humain permettant d’identiEier les différents métabolites phosphorylés à haute énergie. Ces résultats s’inscrivent dans un projet de plus grande envergure où les impacts des changements du métabolisme énergétique sont étudiés en relation avec l’âge et les pathologies.fr
dcterms.abstractAlthough magnetic resonance imaging (MRI) provides a wide array of anatomical and functional contrasts, clinical MRI systems are typically limited to imaging of tissue water and spectroscopy based on hydrogen atoms in more complex molecules. Given the important role of phosphate metabolism in virtually all biological processes, there has been considerable interest in the development of technology allowing detection and spectroscopy of magnetic resonance signals associated with phosphorus in the human body. This poses a number of technical challenges, due to the lower natural abundance and resonant frequency of phosphorus. The objective of this project was to develop and implement a basic in vivo phosphorus capability on a clinical 3 Tesla MRI scanner. We present here the various steps toward building and testing a working prototype of MR coil tuned to phosphorus frequency. We also provide information on building a set of test phantoms required for this project that can be used for signal calibration. Finally we show preliminary phosphorus spectra from muscle, in human subjects, demonstrating the main constituents in high-energy phosphate metabolism. These results pave the way for future applications in which the metabolic physiology of the human brain will be studied during aging and in disease.fr
dcterms.languageengfr


Fichier·s constituant ce document

Vignette

Ce document figure dans la ou les collections suivantes

Afficher la notice

Ce document diffusé sur Papyrus est la propriété exclusive des titulaires des droits d'auteur et est protégé par la Loi sur le droit d'auteur (L.R.C. (1985), ch. C-42). Il peut être utilisé dans le cadre d'une utilisation équitable et non commerciale, à des fins d'étude privée ou de recherche, de critique ou de compte-rendu comme le prévoit la Loi. Pour toute autre utilisation, une autorisation écrite des titulaires des droits d'auteur sera nécessaire.